亚洲免费观看高清完整版在线观看-中文字幕制服丝袜-国内外成人免费视频-超碰青娱乐-国产精品二区一区二区aⅴ污介绍-伊人青青草原-国产性猛交xxxx免费看久久-葵司免费一区二区三区四区五区-精品久久久久一区-久久天堂色-越南午夜性猛交xxxx-红桃视频成人在线观看-99精品国产视频-久久黄色成人-日韩电影 中文字幕

Recombinant Protein G Sepharose FF Gravity Prepacked Column

Recombinant Protein G Sepharose FF Gravity Prepacked Column

【Numbering】BK-NRPB02S 【CAS】CAS
【Item No.】BK-NRPB02S-Z25 【specification】
5 minutes to choose the product plan

E-mail:cro@szbknm.com




Product Name: Recombinant Protein G Sepharose FF


English name: Recombinant Protein G NUPharose Fast Flow, rProtein G NUPharose FF


Catalog number: NRPB02L, NRPB02S (prepacked column)


Specifications: 20 ml, 100 ml, 1 L, 1 ml pre-packed column, 5 ml pre-packed column, special specifications customized


Transportation: 2 ~ 25℃, normal pressure, avoid light


Storage: 20% ethanol, 2 ~ 8℃


Shelf life: 3 years






Related introduction:


Streptococcus Protein G (SPG) is a protein in the cell wall of G and C streptococci. It can specifically bind to the Fc segment of immunoglobulin IgG molecules without affecting the binding of Fab segments to antigen molecules. Ability, its affinity filler can be used to bind, adsorb and purify immunoglobulins (antibodies) from serum, ascites, tissue culture and other supernatants.






Technical index:



基質

4%高度交聯瓊脂糖凝膠

配基

重組蛋白G

配基密度

≥6 mg/ml

填料粒徑

60 ~ 180 μm

最大流速

800 cm/h

推薦流速

20 ~ 100 cm/h

工作(清洗)pH

2 ~ 9(2 ~ 10)

耐反壓

0.3 MPa

載量

≥40 mg/ml IgG


抗體與蛋白A、蛋白G的結合力:

種類

Species

亞型

Antibody Class

蛋白A

Protein A

蛋白G

Protein G

Human

IgG1

IgG2

IgG3

IgG4

IgM

IgD

IgA

Fab

+++

+++

+

+++

+

-

+

+

+++

+++

+++

+++

-

-

-

+

小鼠

Mouse

IgG1

IgG2a

IgG2b

IgG3

IgM

+

+++

+++

+++

-

++

+++

+++

+++

-

大鼠

Rat

IgG1

IgG2a

IgG2b

IgG2c

+

-

-

+++

++

+++

+

+++

Cow

IgG1

IgG2

+

+++

+++

+++

山羊

Goat

IgG1

IgG2

+

+++

+++

+++

Horse

IgG(ab)

IgG(c)

IgG(T)

+

+

-

-

-

+++

兔Rabbit

IgG

+++

+++

豬Pig

IgG

+++

+

狗Dog

IgG

+++

+

雞Chicken

IgY

-

-


Note:-means no combination; + means weak combination; ++ means medium combination; +++ means very strong combination.






Application examples:


Binding buffer: 20 mM phosphate buffer (PB), pH 7.4


Elution buffer: 0.1 M glycine-hydrochloric acid buffer, pH 2.7


Neutralization buffer: 1 M Tris-HCl, pH 9.0


1) 1 ml recombinant protein G sepharose gel pre-packed column, wash away the preservation solution with 5-10 column volumes of distilled water;


2) Equilibrate 5-10 bed volumes with binding buffer;


3) Dilute 5 ml of rabbit polyantiserum to 50 ml with binding buffer, filter and load with 0.45 μm filter membrane;


4) Equilibrate 5-10 column bed volumes with binding buffer to baseline;


5) Elute the antibody with elution buffer, collect the elution peak, and adjust its pH to neutral with neutralization buffer;


6) Regenerate and clean with 3 ~ 5 column bed volumes of elution buffer after each use;


7) The purity of the rabbit polyclonal antibody eluted by SDS-PAGE (Figure 1) electrophoresis analysis is above 95%.



圖片29.jpg圖片30.jpg

圖 1


Precautions:


1) The pre-packed column is easy to use and can complete the purification task without equipment.


2) After the sample is eluted, the pH is generally very low, and the collected antibody solution should be neutralized to neutral with an alkaline neutralization buffer (such as 1 M Tris-HCl, pH 9.0) immediately, or pre-filled in the collection container 5% ~ 20%, pH 7 ~ 9 buffer (such as 1 M Tris-HCl or 1 M phosphate buffer) to help maintain the biological activity of the antibody and avoid antibody inactivation.


3) When using, ensure that the temperature of the column and the buffer are the same to avoid bubbles in the column bed and affect the purification effect. If bubbles have already occurred, you can repack the column by yourself.


4) Normally, after the target sample is eluted, continue to wash 3 to 5 column volumes with 0.1 M glycine-hydrochloric acid buffer (pH 2.0 ~ 2.7), and then wash more than 5 column volumes with equilibration buffer for simple regeneration.


5) In-place cleaning should be performed after several times of use. It is recommended to wash 1 to 3 column volumes (10 to 30 min) with 0.1% Triton X-100 at 37°C, and immediately wash more than 5 column volumes with equilibration buffer; or 70 Wash with% ethanol for more than 5 column volumes (can be maintained for 4-6 h), and then wash with equilibration buffer for more than 5 column volumes. Cleaning-in-place can remove strong hydrophobic proteins and lipids and restore the load and flow rate of the column.



Warm tips: Suzhou Beike nano products are only used for scientific research, not for human body,different batches of products have different specifications and performance

Message

Name: *
Mobile: *
E-mail: *
Content:
 
Scan code concerns WeChat official account
QQCommunication group:1092348845
Warm tips: Suzhou Beike nano products are only used for scientific research, not for human body,different batches of products have different specifications and performance.The website pictures are from the Internet. The pictures are for reference only. Please take the real object as the standard. In case of infringement, please contact us to delete them immediately.
    重組蛋白G瓊脂糖凝膠FF重力預裝柱

Previous: the end...

Next: Dextrin Sepharose FF

advisory
phone
cro@szbknm.com
Tel:+8618915694570
scan

scan
WeChat